What to do if the PP plastic hollow board production equipment malfunctions during operation

DATE:2023/9/23 10:51:35 / READ: / SOURCE:This station

It is a common situation for PP plastic hollow board production equipment to malfunction during operation, and timely measures need to be taken to solve the problem to ensure normal production. Below will introduce some common faults and their solutions.


1. Equipment shutdown: If the equipment suddenly stops, the first step is to check whether the power supply is normal and ensure that the equipment has sufficient power supply. Secondly, check if the fuse of the equipment is blown, and if so, replace it with a new fuse. Also check if the switch of the device is normal. If the switch is in the off state, it needs to be turned on. If none of the above methods can solve the problem, it may be due to a malfunction in the internal circuit of the equipment, which requires professional technical personnel to repair.
2. Excessive equipment noise: If abnormal noise is generated during equipment operation, it may be due to loose or worn internal components of the equipment. At this point, it is necessary to stop the machine and inspect the transmission components of the equipment, such as belts, chains, bearings, etc., to ensure that they are securely installed and not worn. If loose or worn components are found, they need to be repaired or replaced in a timely manner.
3. Unstable equipment operation: If the equipment experiences shaking or instability during operation, it may be due to an unstable foundation of the equipment or a problem with the internal transmission system of the equipment. Firstly, it is necessary to check whether the foundation of the equipment is flat and stable. If it is not flat, adjustments need to be made. Secondly, check whether the transmission components of the equipment are normal, such as belts, chains, gears, etc., to ensure that they are installed correctly and without wear. If none of the above methods can solve the problem, it may be that the transmission system of the equipment needs to be repaired or replaced.
4. Equipment temperature too high: If the temperature is too high after the equipment has been running for a period of time, it may be a problem with the cooling system of the equipment. Firstly, it is necessary to check whether the cooling system of the equipment is working properly, such as fans, radiators, etc., to ensure that they operate normally and are not clogged. If the cooling system is normal, it may be due to a malfunction in the motor or electrical components of the equipment, which requires professional technical personnel for repair.
5. Equipment leakage: If water leakage occurs during equipment operation, it may be due to damage to the sealing components of the equipment or loose pipeline connections. Firstly, check the sealing components of the equipment, such as sealing rings and gaskets, to ensure that they are intact and undamaged. Secondly, check whether the pipeline connections of the equipment are tight. If looseness or water leakage is found, it needs to be tightened or replaced. If none of the above methods can solve the problem, it may be that the pipeline system of the equipment needs to be repaired or replaced.
In short, it is a common situation for PP plastic hollow board production equipment to malfunction during operation, but as long as we take the correct solutions in a timely manner, the normal operation of the equipment can be quickly restored. When solving faults, it is necessary to pay attention to safety and ensure the personal safety of operators and the safety of equipment. In addition, regular maintenance and upkeep of equipment can reduce the occurrence of faults and extend the service life of the equipment.